Port recommendations for connecting common environmental sensors:

ManufacturerSensorPort
AanderaaOxygen Optode 4175P0, P1
BenthosPSA-916 AltimeterP1
FTSDTS-12P1
HydrolabDS5, MS5 SondesP0
In-SituAqua TROLL 100/200P0
RDO PRO Optical DO sensorP0
ISCO6700 Series samplersD
2150 Area Velocity Flow ModuleP0
LI-CORLI-190, LI-192, LI-193, LI-200A
LufftWS Weather sensorsP0
NexSensAccuStage  level sensorP0
Long T-Node stringP0
Short T-Node string
(<14 sensors or <15 m length)
T
NortekAquadopp current ProfilerP0
OTTRLS Radar level sensorP0
PonselPonsel Digital SensorsP0, P1, T
RM Young05103V, 05103V-45 Wind monitorsA
SonTekArgonaut SW, SL, XRP1
TritechMicron echo sounder DSTP1
Turner DesignsC3 submersible fluorometerP1
C6 multi-sensor platformP1
Cyclops-7 submersible fluorometerA
SCUFA submersible fluorometerP0
VaisalaWXT520 mutli-parameter weather sensorP0
YSI6-Series sondesP0, P1

 

The above are meant to be recommendations only. In most cases, there is more than one port that a sensor can connect to. If the recommended port is already in use, see the pin specific signal information for each port to determine another suitable location to connect and operate the sensor from.

Bottom Sensor Bulkhead Pin-specific signal information:

PinP0P1TDA
1

485A

485A

485A

485A

AD12

2

485B

485B

485B

485B

AD13

3

SDI-12

SDI-12

SDI-12

SDI-12

AD14

4

BAT

SW12V

SW12V

BAT

SW12V

5

SW5V

SW5V

SW5V

SW5V

DA1

6

P0.Rx

P1.Rx

1-Wire

RAIN

AD15

7

GND

GND

GND

GND

GND

8

P0.Tx

P1.Tx

P2.Rx

DIO0

AGND

Note: Internal batteries are required for communication through iChart software when any sensor that requires more than 5 VDC is connected to the SDL500. If a desired sensor is not listed, refer to the appropriate sensor interface manual or contact NexSens Customer Support.