The logged data on an X2 data logger can be cleared via CONNECT. This deletes all stored measurements from the X2 memory, and the data can no longer be recovered once erased. Connect the X2 logger to a PC and launch the CONNECT software. From the CONFIG tab, click the drop-down arrow next to the […]
Articles Tagged: X2 data logger
Direct Data Upload
Upload data from any X2 data logger to an Excel-compatible .csv file via direct connection using the CONNECT software and a UW6-USB-485P cable. Upload Data Manually from an X2 Logger Connect the X2 logger to a PC and launch the CONNECT software. Test connection by reading the RTC clock of the logger in the CONFIG […]
Mount an X2 Environmental Data Logger
The X2’s mounting kit accessory provides an easy way to attach the logger to a pole, pipe or wall. Mount an X2 to a 1-1/2 to 2″ (38 to 50 mm) pole by following the instructions in this guide. Alternatively, user-supplied screws may be used to mount an X2 to a wall. X2 Mounting Kit […]
Desiccant Replacement
Each X2 ships with a bag of desiccant placed underneath the data logger circuit boards. Replace this desiccant bag whenever: The X2 enclosure is opened. Moisture from condensation appears on the inside surface of the enclosure lid. The Internal Humidity diagnostic parameter reads 50% or greater. Use a desiccant pack provided by NexSens or any […]
Configure Network Settings
Wi-Fi only models of the X2 data logger can be configured to upload to the WQData LIVE datacenter over a local wireless network. To configure network settings: Establish a connection to the X2’s direct Wi-Fi network. Access the main menu by clicking the menu icon in the top right. Navigate to Settings | Network. […]
X2 LED Indicator Lights
The X2 contains two sets of (4) LEDs visible through the lid of the enclosure. These X2 LED indicator lights give insight into the operation of the data logger and Wi-Fi module, respectively. Two additional green LEDs beneath each magnet port give feedback when the magnet input is triggered. Note that all LED operation is […]
X2 Data Flow
The X2 is designed to provide real-time data to users, most commonly via the WQData LIVE web datacenter. The diagrams below outline how the data travels from sensor to user. Wi-Fi Cellular Iridium Radio to Cellular Radio to PC Notes: Data is posted to WQData […]
Connect to an X2 via Wi-Fi Direct
Most X2-series data loggers are equipped with on-board Wi-Fi Direct communications which can be used for logger configuration and/or transmission of data to the WQData LIVE web datacenter. Turn On Wi-Fi Outside of a scheduled transmission period, the Wi-Fi is powered off and must be activated to establish a connection. The primary method used to […]
Brushy Creek Designated Uses
University of Louisville
When Brushy Creek in Kentucky was not meeting designated uses under the Clean Water Act, University of Louisville scientists contacted NexSens.