Sensor Accessories
Adapters, cables and sensor mounts
-
NexSens 3/16″ Stainless Steel Mooring Lines
Custom built 3/16" (1/4" OD) vinyl coated SS mooring lines provide plenty of holding power for securing underwater deployments.
-
NexSens 8 Conductor Polyurethane Cable
NexSens SDL100 cable features 8 conductors, 22 AWG, and a rugged polyurethane jacket designed for outdoor and underwater applications.
-
NexSens A50 Junction Box
The A50 Junction Box simplifies the process of wiring multiple sensors into a data logger.
-
NexSens Anti-Chafing Sensor Cable Armor
NexSens anti-chafing sensor cable armor is a 3/8" ID EPDM rubber hose that is installed to sensor cable and secured via cable ties.
-
NexSens EXO Sonde Bottom Platforms
The NexSens EXO sonde bottom platforms offer a turnkey solution for bottom deploying a YSI EXO multi-parameter water quality sonde.
-
NexSens EXO Sonde Mooring Cages
The NexSens EXO Sonde Mooring Cages provide a secure and convenient means of deploying a YSI EXO multi-parameter water quality sonde.
-
NexSens EXO Sonde Mooring Clamp Sets
The NexSens EXO Sonde Mooring Clamp Sets provide a secure and convenient means of deploying a YSI EXO multi-parameter water quality sonde.
-
NexSens Instrument Mooring Clamp
The NexSens sonde mooring clamps are designed to securely attach multi-parameter sondes and other water quality sensors along a mooring line in buoy-based applications.
-
NexSens ISCO to EXO Sonde Cable Adapter
The ISCO to EXO Sonde Cable Adapter offers a convenient, waterproof connection between an ISCO 6712 autosampler and a YSI EXO water quality sonde.
-
NexSens LI-192 Underwater PAR Sensor Mounting Arm
The M-ARM-P mounting extension is used to mount a LI-COR LI-192 underwater PAR sensors and Zebra-Tech Hydro-Wiper to a subsurface instrument cage.
-
NexSens LI-193 Spherical PAR Sensor Cage Mount
The NexSens LI-193 spherical PAR sensor cage mount securely attaches the LI-COR LI-193 sensor to the instrument cage on CB-Series buoy platforms.
-
NexSens LI-COR Terrestrial Sensor Mounting Arm
The M-ARM mounting extension is used to mount LI-COR solar radiation and PAR sensors to 2" poles.
-
NexSens Lufft WS-Series Sensor Configuration Cable
The NexSens WSConfig cable includes a USB connector and AC power supply to configure the Lufft family of multi-parameter weather sensors.
-
NexSens MCBH Female Bulkhead Connectors
Female wet mateable bulkhead connectors
-
NexSens MCBH Male Bulkhead Connectors
Male wet mateable bulkhead connectors
-
NexSens MCDC Female Dummy Plugs
Female wet mateable dummy plugs
-
NexSens MCDC Male Dummy Plugs
Male wet mateable dummy plugs
-
NexSens MCDLS-F Female Locking Sleeve
Female locking sleeve with spiral retaining ring for MCIL cables and MCBH bulkhead connectors.
-
NexSens MCDLS-M Male Locking Sleeve
Male locking sleeve with spiral retaining ring for MCIL cables and MCBH bulkhead connectors.
-
NexSens MCIL Female Cable Assemblies
Female wet mateable cable assemblies with locking sleeves are available for interfacing with a variety of water quality instruments.
-
NexSens MCIL Female Cable Connectorization
The NexSens MCIL female cable connectorization service includes assembly, test, and setup of user-supplied sensor cables for communication to X3-SUB data loggers.
-
NexSens MCIL Male Cable Assemblies
Male wet mateable cable assemblies with locking sleeves are available for interfacing with a variety of water quality instruments.
-
NexSens mV to RS-485 Signal Adapter
The NexSens mV-RS485 signal adapter converts a standard mV output signal to RS-485, allowing analog sensors to be integrated into an X-Series data logger or sensorBUS string.
-
NexSens RS-232 to USB Adapter
The RS-232 to USB adapter is used for interfacing instruments with computers that do not have available DB-9 serial port connections.
-
NexSens RS-232 UW Sensor USB Adapter
The NexSens RS-232 UW sensor USB adapter allows users to connect RS-232 sensor cables terminating in UW plug connectors to a PC for configuration, troubleshooting, etc.
-
NexSens RS-485 MCIL Sensor USB Adapters
The NexSens RS-485 MCIL sensor USB adapter allows users to connect mV-RS485-MC adapters and other RS-485 sensors terminating in a NexSens MCIL-8-FS connector to a PC for configuration.
-
NexSens RS-485 to RS-232 Adapter
The RS-485-RS-232 adapter converts RS-485 sensors to RS-232 and vice versa for use with thermistor strings and water quality sensors.
-
NexSens RS-485 UW Sensor USB Adapters
The NexSens RS-485 UW sensor USB adapter allows users to connect T-Node FR/TS210 sensors, mv-RS485-UW adapters, and other RS-485 sensors terminating in a UW plug connector.
-
NexSens Small Instrument Cage Mount
The NexSens cage mount is designed to securely attach multi-parameter sondes and other water quality sensors to an instrument cage in buoy-based applications.
-
NexSens T-Bumper Sensor Cable Guard
The T-Bumper sensor cable guard is designed to prevent cable chafing when deploying instruments in buoy deployment pipes.
-
NexSens Thermistor String Mooring Clamp Kit
The NexSens TS-Clamp mooring clamp is designed to securely attach a string of TS210 or T-Node FR temperature sensors along a mooring line in buoy-based applications.
-
NexSens Tipping Bucket Rain Gauge Mount
The 3510-M is an aluminum mounting plate used for securing an 8" diameter tipping bucket rain gauge to a 2" diameter pole with male NPT pipe threads.
-
NexSens UW 2-Way Sensor Splitter
The 2-way sensorBUS signal splitter connects SDI-12 or RS-485 sensors in-line along T-Node FR temperature strings or expands the number of sensor ports on an X3 data logger.
-
NexSens UW 4-Way Sensor Splitter
The 4-way sensorBUS signal splitter connects SDI-12 or RS-485 sensors in-line along T-Node FR temperature strings or expands the number of sensor ports on an X2 data logger.
-
NexSens UW Cable Connectorization
The NexSens UW cable connectorization service includes assembly, test, and setup of user-supplied sensor cables for communication to X-Series data loggers.
-
NexSens UW Extension Cables
Designed for harsh environments in fresh, brackish, or seawater, these UW extension cables offer flexibility in extending cable runs or building T-Node FR temperature strings.
-
NexSens UW Field Wireable Plug
Field wireable plug designed to allow easy connection from a flying lead sensor cable to a standard NexSens UW-8 receptacle.
-
NexSens UW Plug to Flying Lead Cables
The UW plug to flying lead cable is used to wire external sensors to the X-Series data loggers.
-
NexSens UW Receptacle to Flying Lead Cables
The UW receptacle to flying lead cable is used for wiring sensors with integrated UW plug connectors to a data logger terminal strip.
-
NexSens UW Sensor Plug Connector Cap
Sensor receptacle caps are used to provide a waterproof seal on cables with UW plug connectors when servicing or removing sensors from buoys and X2 data loggers.
-
NexSens UW Sensor Port Plug
Sensor port plugs can be used to provide a watertight seal around unused data logger ports or the free end of T-Node FR/TS210 temperature strings during deployments.
-
NexSens UW to EXO Sonde Cable Adapters
The UW-EXO is used to connect YSI EXO water quality sondes to NexSens X-Series data loggers or UW underwater cable assemblies.
-
NexSens UW to EXO3 Sonde Cable Adapters
The NexSens UW-EXO-x cable adapter is used to connect an EXO3/EXO3s sonde directly to a NexSens X-Series data logger.
-
NexSens UW to LI-COR Underwater Sensor Cable Adapter
The UW-LI-3 cable is used to connect LI-COR LI-192 and LI-193 underwater PAR sensors to NexSens X-Series data loggers via UW plug waterproof connector and mV-RS485 adapter.
-
NexSens UW to LISST-ABS/AOBS Sensor Cable Adapters
The NexSens UW-ABS cable adapter is used to connect a LISST-ABS or LISST-AOBS sensor directly to a NexSens X2 data logger.
-
NexSens UW to Twist-Lock Cable Adapter
The UW to Twist Lock cable adapter is used to connect In-Situ Aqua TROLL probes/sondes to NexSens X-Series data loggers via UW plug waterproof connector.
-
NexSens UW to YSI 6-Series Sonde Cable Adapter
The UW-6091 cables are used to connect YSI 6-Series water quality sondes to NexSens X-Series data loggers via UW plug waterproof connector.
-
NexSens Vaisala WXT-Series Sensor Mounting Arm
The M-ARM-E mounting extension is used to mount Vaisala and RM Young meteorological sensors to 2" poles.
-
NexSens Vaisala WXT-Series Weather Sensor Mount
The WXT510-M is a PVC mount used for attaching Vaisala WXT-Series weather sensors and RM Young weather sensors to a 2" diameter pole with male NPT pipe threads.
-
NexSens Water Quality Sonde Flow Cell
The NexSens Flow-C is a high quality flow cell designed for water quality sonde process monitoring in water treatment plants.