Backdoor Communication for Lufft Weather Stations
Lufft weather stations use a universal address (ID = 200) in the instance that the device ID is unknown. For pre-configured sensors with altered communication protocols, there is a 10-second window after powerup where it is set to the default UMB protocol, and the software can communicate. If the communication protocol on a Lufft device has been changed, follow the backdoor communication technique for reconnecting the device in the Configtool.NET software.
Known Device IDs
If the Device ID is known,
- Open a new or existing workspace and create a device with the proper device class (WSx-UMB) and ID.
- Click on the device.
- Hit the gear icon at the top of the “Device Details” page.
- Cycle power on the Lufft.
- The “Not connected” display will now show “Connected” with the device information.
- Click “Read from Device” to see the sensor configuration.
Unknown Device IDs
If the Device ID is not known,
- Open a new or existing workspace and create a device with the proper device class (WSx-UMB) and an ID of 200.
- Click on the device.
- Hit the gear icon at the top of the “Device Details” page.
- Cycle power on the Lufft.
- The “Not connected” display will now show “Connected” with the device information.
- Click “Read from Device” to see the sensor configuration.