NexSens TS-Clamp thermistor string mooring clamps allow TS210 and T-Node FR nodes to be securely attached to a mooring line. Follow these steps to ensure a proper installation of the TS-Clamp: 1. Unscrew the TS-Clamp to find two o-rings with cuts. 2. Place the large o-ring on the cable above the strain relief of […]
T-Node FR
Connecting a T-Node FR or TS210 String to a Modbus Master
NexSens T-Node FR and TS210 temperature strings have an RS-485 Modbus output that allows direct connection to a Modbus master device (i.e. PLC). To connect the string, a UW receptacle to flying lead cable is required. These cables are available in lengths ranging from 1m to 100m. The wiring for the T-Node FR or TS210 […]
T-Node FR Troubleshooting
Symptom Possible Cause Corrective Action Temperature data is displayed as a value between -99999 and -100001 Leakage into a connector Check each underwater connection for flooding String disconnected (or severed cable) Check the physical setup and condition of the temp string No Power If connected to port P1 or T ensure switch power is setup […]
T-Node FR Maintenance
Very little maintenance is required for T-Node FR temperature strings because they are designed for long-term deployments in submersible applications. Cleaning Any bio-fouling that accumulates on T-Node FR temperature strings during deployments should be cleaned using a soft cloth or soft-bristled brush along with soap and water. Never allow moisture to enter any of the […]
Attaching T-Node FR Sensors to a Mooring Line
Temperature strings are frequently attached to mooring lines to keep them fixed in place vertically within a water column. This technique helps to ensure that temperature data is consistently being monitored at desired depths. To mount the T-Node FR sensors to a mooring line, T-clamp sensor mooring clamps, cable ties and a mooring line will […]
Connecting T-Node FR to an iSIC Data Logger
T-Node FR sensors can be connected to any iSIC data logger using a UW receptacle to flying lead cable assembly. First, plug the temperature string into the UW receptacle. Run the cable through a gland fitting on the bottom of the iSIC enclosure. Then, wire the flying lead end of the cable into […]
Connecting T-Node FR to SDL500
UW underwater connectors provide a plug-and-play interface for connection to NexSens SDL500 Submersible Data Loggers. The SDL500 sensor bulkhead includes sensor connection ports identified as T, P1, P0, A and D. T-Node FR sensors and strings can be connected to Ports P0, P1, T, or D. It is recommended to connect to port […]
T-Node FR Temperature String Assembly
Single-Point Temperature String Assembly Single-point strings are used to determine water temperature at one location, typically at the surface. To assemble a single-point temperature string, first connect the male UW plug connector on the T-Node FR to the female UW receptacle connector on an Underwater Cable. Then connect the supplied UW underwater plug […]
T-Node FR Specifications
Specifications Length 5.3 in (134.6 mm) Diameter (OD) 1.4 in (35.6 mm) Weight 0.3 lbs Housing Acetal CopolymerPolyvinylchloride (PVC) Operating Temp Range -25 to 75ºC Operating Depth Range 4000 ft Sensor Capacity 250 nodes Output RS-485 Modbus RTU Warmup Time 10 sec Reading Time 1 sec Power Requirements Voltage: 5 to 24 VDC Power […]
T-Node FR What’s Included & Accessories
Each T-Node FR Water Temperature Sensor includes the O-rings required for preventing leakage and cracking between sensors. UW underwater bushings are also included as required for temperature string terminations. Strings are usually assembled using NexSens underwater cable assemblies. Common Accessories Part Number Description Details UW Underwater cable Used for assembling T-Node temperature strings, various lengths […]