Cycling Power to an iSIC or SDL

    It may be necessary to reset an iSIC or SDL by manually cycling power. This will allow the system to reboot and can solve various problems. iSIC 1. Open the lid of the iSIC enclosure. 2. Remove both black fuses located to the left of the digital terminal strip. While the fuses are removed, check […]

    Read More

    Input/Output Control

    The iSIC is capable of adjusting various settings based on a parameters reading. The enable line can be triggered, the sample interval can be changed, and various other configurations adjustments can be made. 1. Open iChart with the current project file. Note: Interrogate all data off of the device as this process will require the […]

    Read More

    Change COM Port

    If a different computer than the one used to create the project is being used to download data, it is likely that the COM port will need to be switched. To determine which COM port the data logger is using, please follow the instructions in Verifying iSIC/SDL COM port. 1. Open iChart with the current project file. 2. Right-click […]

    Read More

    Update Firmware With RS-485 Cable

    In order to update a SDL’s firmware using a UW-USB-485P communicaiton cable, the communication protocol must be changed to RS-485. 1. Establish temporary RS-485 communicaiton with the device by following the steps in the Direct connection with an SDL500 via RS-485 article. 2. From the menu bar select Edit | Preferences. 3. Switch to the GUI tab. 4. Check the “Enable […]

    Read More

    Changing the Address of an iSIC or SDL500 Data Logger

    The address of an iSIC or SDL500 data logger can be changed using iChart software. 1. Open iChart with a current project if not already open 2. From the menu select Advanced | iSIC | iSIC 3. Select the correct PC COM port, Connection type and iSIC Address If the address is unknown and the connection […]

    Read More

    6100-MAST Quick Start Guide

    Overview The NexSens 6100-MAST arrives fully preconfigured with a cellular data logger and 20-watt solar panel. The setup incorporates an integrated Iridium satellite modem and over-the-air communication to transmit data from anywhere on Earth. What’s Included Data logger with Iridium satellite modem 20-Watt solar power kit Cellular antenna with mounting bracket RF cable Pole mounting […]

    Read More

    6100-iSIC Quick Start Guide

    Overview The NexSens 6100-iSIC (Intelligent Sensor Interface and Control) data logger uses an integrated Iridium satellite modem for data transmission. This type of communication is used when other telemetry options are not feasible. What’s Included Data logger with Iridium satellite modem 12 VDC battery iSIC Kit (2) Gland fittings (5) Desiccant packs RS-232 interface cable […]

    Read More

    6100-iSIC Light Pattern

    After a power cycle, the iSIC’s LED will blink in a certain pattern to indicate the startup progress. The following flow chart will help diagnose the current status of a 6100-iSIC data logger.   REV: 13G18  

    Read More

    Changing an iSIC Battery

    The battery that powers an iSIC data logger is user-replaceable. 1. Disconnect the fastons from the battery terminals inside the iSIC. 2. Remove the two screws on the battery plate with a #3 Phillips head screwdriver. Store the battery plate and screws.   3. Remove the old battery and put the new battery in its […]

    Read More

    Millivolt (mV) Readings on an Analog Sensor

    Analog sensors require a millivolt (mV) reading in order to determine an accurate output. To find these readings, follow the process below. 1. Open iChart without a project file. 2. Select Advanced|iSIC|iSIC from the menu bar. 3. Select the appropriate communication under PC Settings. 4. Type the address of the data logger and click Connect.   5. Click the Analog tab. […]

    Read More