If an SDI-12 sensor reading shows -99999.99 or -100000 in iChart, it indicates that there is a communication problem between the data logger and the SDI-12 sensor. In this situation, there are several possibilities: 1. Insufficient power supply 2. Loose wiring between the logger and sensor 3. The data logger SDI-12 interface is not functioning […]
5500-iSIC
iSIC Multiple SDI-12 Sensors
Multiple SDI-12 Sensors can be wired to the same digital terminal strip. Up to ten SDI-12 devices can be connected to the SDI-12 pin on the iSIC Data logger. Any NexSens iSIC data logger can “pass-through” telemetry and allow SDI-12 commands to be sent directly to the sensor. Because each sensor in a multiple SDI-12 […]
iSIC Sensor Interface
RS232 In addition to the single RS232 port located externally on the iSIC via the MS8 connector, three RS232 ports are available on the internal Digital terminal strip. Ports 1, 2, and 3 are available for use. To connect your RS232 sensor to the iSIC, open the enclosure, unscrew the correct pins on the terminal strip, […]
iSIC Data Logger Overview
Components The enclosure that houses the NexSens iSIC Printed Circuit Board (PCB), wiring, and battery is a durable NEMA 4X enclosure. It measures 12” x 8” x 7” (inches) and is constructed of heavy-duty fiberglass. This enclosure is certified for both indoor and outdoor use. Falling dirt, rain, sleet, snow, windblown dust, splashing water, hose-directed […]