X3-SUB Submersible Data Logger X3-SUB Submersible Data Logger
X3-SUB Submersible Data Logger X3-SUB Submersible Data Logger

X3-SUB Submersible Data Logger

The X3-SUB is a rugged, self-powered remote data logging and telemetry system specifically designed for offshore use without fear of accidental flooding.

Features

Rugged

The X3-SUB is designed with Type 316 stainless steel, shock-mounted electronics and redundant seals. It can withstand extreme wave action, floods and underwater deployment to 100m.

Rugged Rugged

Rugged

The X3-SUB is designed with Type 316 stainless steel, shock-mounted electronics and redundant seals. It can withstand extreme wave action, floods and underwater deployment to 100m.

Rugged Rugged

Wet-Mate Connectors

All connections are made with MCIL/MCBH wet-mate connectors. This removes the complications and errors associated with connecting individual wires.

Wet-Mate Connectors Wet-Mate Connectors

Wet-Mate Connectors

All connections are made with MCIL/MCBH wet-mate connectors. This removes the complications and errors associated with connecting individual wires.

Wet-Mate Connectors Wet-Mate Connectors

Multiple Power Options

The X3-SUB is supplied with an internal sealed lead acid battery for use with the CB-75 Data Buoy's solar panels. Alternatively, the logger can operate from external 12 VDC power.

Multiple Power Options Multiple Power Options

Multiple Power Options

The X3-SUB is supplied with an internal sealed lead acid battery for use with the CB-75 Data Buoy's solar panels. Alternatively, the logger can operate from external 12 VDC power.

Multiple Power Options Multiple Power Options

Device-to-Web

When communicating via wireless telemetry, measurement data streams directly to the WQData LIVE Web Datacenter.

Device-to-Web Device-to-Web

Device-to-Web

When communicating via wireless telemetry, measurement data streams directly to the WQData LIVE Web Datacenter.

Device-to-Web Device-to-Web

Communication Options

Real-time telemetry options include 4G LTE cellular and Iridium satellite. All communication modules are securely housed within the submersible enclosure, and a waterproof antenna is integrated on the top of the device.

Communication Options Communication Options

Communication Options

Real-time telemetry options include 4G LTE cellular and Iridium satellite. All communication modules are securely housed within the submersible enclosure, and a waterproof antenna is integrated on the top of the device.

Communication Options Communication Options

Measurement Versatility

The X3-SUB is configured with three sensor ports to interface with multi-parameter sondes, water quality sensors, temperature strings, Doppler velocity meters, water level sensors, and more. Supported sensor interfaces include SD-12, RS-485 and RS-232.

Measurement Versatility Measurement Versatility

Measurement Versatility

The X3-SUB is configured with three sensor ports to interface with multi-parameter sondes, water quality sensors, temperature strings, Doppler velocity meters, water level sensors, and more. Supported sensor interfaces include SD-12, RS-485 and RS-232.

Measurement Versatility Measurement Versatility

Buoy Integration

The CB-75 data buoy is designed to accommodate the NexSens X3-SUB submersible data logging system for unattended deployment in lakes, rivers, and coastal waters.

Buoy Integration Buoy Integration

Buoy Integration

The CB-75 data buoy is designed to accommodate the NexSens X3-SUB submersible data logging system for unattended deployment in lakes, rivers, and coastal waters.

Buoy Integration Buoy Integration

Tech Specs

Material: Type 316 stainless steel
Weight: 8.2 lbs. (3.72kg); 12.2 lbs. (5.53kg) with rechargeable battery; 14.1 lbs. (6.40kg) with alkaline battery
Dimensions: 5.5" (13.97cm) diameter with 7.25” (18.42cm) flange x 14.63" (37.16cm) height
Internal Power Options: 6 A-Hr SLA rechargeable battery or 20 D-cell alkaline battery pack
External Power Requirements: 10.7 to 16.8 VDC +/-5%; includes reverse polarity protection, over voltage protection (OVP), and under voltage lock out (UVLO) protection
Current Draw (Typical @ 12VDC): Sleep: 450uA; Active: 55mA; Cellular transmitting: 300mA; Iridium satellite transmitting: 170mA
Peak Current: Power supply must be able to sustain a 500mA 1-second peak current (@ 12V)
Operating Temperature: -40°C to 70°C
See Full Specs
Rating: IP68
User Interface: Wireless Bluetooth or wired RS-485 via USB adapter to CONNECT Software; WQData LIVE Web Datacenter with optional wireless telemetry; Status beeps
Real Time Clock (RTC): <30sec/month drift1; Auto-sync weekly2; Internal backup battery
Data Logging: 8 MB non-volatile flash memory; >1 year storage with 20 parameters at 15-minute interval; Max 200 parameters per log interval
Log Interval: User configurable from 1-minute (10-minute default)3; Unique interval per sensor
Transmit Interval: User configurable from 5-minute (10-minute default)
Transmission Trigger: Time-based; Selective parameter upload option
Sensor Interfaces: RS-232 (3 Channels), SDI-12, RS-485, Pulse Count
Sensor Power: (2) independent switches from input supply4,5
Built-in Sensors: Temperature (-40° to 100°C, 0.016°C resolution, ±0.3°C accuracy); Humidity (0% to 100%, 0.03% resolution, ±4% accuracy from 5 to 95% RH; System voltage; System current; System power; Real-time clock (RTC) battery voltage
Sensor Ports: (3) MCBH-8-MP for sensor interface (RS-232, RS-485, SDI-12, Power, GND)
Power Port: (1) MCBH-6-FS for power and communication (12V Solar In, Power Switch, RS-485 Host, GND)
Telemetry Options: 4G LTE global cellular; Iridium satellite
Antenna Port: Type N female

Notes

1 Assumes 25ºC operating temperature
2 Requires the X3-SUB to be connected to the internet
3 Minimum log interval dependent on sensor limitations and processing time
4 Cumulative concurrent current limit of all three channels is 2A
5 Logger power supply must be able to support current requirements of sensors

Tech specs image Tech specs image

Q&A

What sensors are compatible with the X3-SUB data logger?
down-arrow
The X3-SUB data logger is compatible with sensors that support a native SDI-12, RS-485, or RS-232 output. The X3-SUB also supports tipping bucket rain gauges. Analog sensors (0-5 VDC, 4-20mA, etc.) can be integrated using an analog-to-digital adapter (mV-RS485-MC).
How are sensors connected to the X3-SUB data logger?
down-arrow
The X3 data logger utilizes industry-standard MCIL/MCBH wet-mate connectors. The sensor ports are 8-pin male (MCBH-8-MP), so a 8-pin female (MCIL-8-FS) connector is needed on the sensor cable. If sensor cables aren't already terminated with this connector, customers can send in their sensor cable for a connectorization service (MCIL-8-FS-X). Alternatively MCIL-8-FS-1 pigtail cables are available for customers to wire/splice at their facility.
What power options are available for the X3-SUB data logger?
down-arrow
The most common power scenarios for the X3-SUB data logger are internal SLA battery (BAT-A04) with solar charging from a CB-75 data buoy, internal 20 D-cell alkaline battery pack (BAT-20D), or external 12VDC power from a flying lead cable (MCIL-6-MP-x). For shore-mounted applications, a SA2122 power adapter cable is available to work with any of the X3 data logger power accessories including SP-Series solar power packs, UW6-PW AC power adapters, and UW6-BB battery backups.
Can the X3-SUB data logger be integrated on a data buoy?
down-arrow
The X3-SUB is IP68 waterproof rated and designed to be integrated on the CB-75/CB-75A data buoys. The data logger could also be integrated on 3rd party data buoy platforms using the internal alkaline battery pack or external 12VDC power.

Get Started

Need help designing an Environmental IoT system? NexSens applications scientists will help you design the perfect monitoring system to meet field conditions and monitoring needs.

REQUEST A QUOTE

Systems

Learn more about environmental system and equipment applications on the NexSens System database.

VIEW ALL SYSTEMS